DW-ST
48 x 96 panel mount WEIGHING Indicator with setpoints and peaks control and totalizer.
DW-ST/B FEATURES

PDF Datasheet

  • Precision class: III - 6000d concerning EN45501 / OIML R76, 15000d not-for-trade.
  • Load Cell Input with a 24 bits A/D Sigma-Delta converter.
  • Enhanced protection against EMI (Electromagnetic interferences)
  • 7 Segments Display of 6 Digits.
  • 14 Led show the state of the indicator.
  • 1 Serial Port RS232C or RS485 to communicate with PC, Printers or Remote displays.
  • 5 Keys Keyboard to use and program the controller.
  • Electronic and mechanical seal.
  • Standard or configurable ticket through PC Utility.
  • Modbus ASCII Protocol.
  • Indicator with mV pre-calibration.
  • Power Supply: 9..30Vdc / 9..24Vac
  • Dimensions: 48x96x116mm.
DW-ST/D FEATURES:
  • Idem DW-ST/B
  • 2 PNP or NPN Opto-isolated Inputs.
  • 2 Relay outputs
DW-ST/F FEATURES:
  • Idem DW-ST/B
  • 2 PNP or NPN Opto-isolated Inputs.
  • 2 Relay outputs
  • Opto-isolated analogical Output: 0-20mA, 4-20mA, 0-5Vdc, 0-10Vdc.
OPERATING MODES:
  • Weight-Tare: Allow to display the weight of a scale, apply tares and untare.
  • Setpoints  & Peak Memory: Allow to manage two setpoints and calculate the peaks values.
  • Accumulator: Allow to accumulate weights and number of weights.
  • Transmitter: Allows to send load cell signals through RS232 or RS485 to any device. 
Configuration Utility of the
weight indicator from any PC.
OPTIONS
  • 2nd RS232 serial port.    
  • USB 2.0 port communication port. 
  • WIFI communication port.
  • Ethernet 10/100M Base T communication port.
  • Time and date.
APPLICATIONS
  • On-Board weighing of movable equipment.
  • Maximum and minimum control level on silos.
  • Simple weight.
  • Communication with PLCs and PC.